Election Forensics 2026 — Part Two of Three
From the electoral map to forensic analysis
In the first article of this series, we saw that the Student List won 53.69% of valid votes in Serbia's 2026 parliamentary election, but that its victory was far from evenly distributed across polling stations. The Vučić list retained an advantage at small polling stations, considerably narrower than the governing lists’ leads over the selected opposition lists in 2022 and 2023. Does this contrast merely reflect differences in the electorate, or does it point to something deserving further forensic investigation?
Imagine examining the same election returns through six different lenses. The first provides an overview, the second identifies where votes accumulate, the third reveals concentrations, the fourth compares stations in their local context, the fifth measures statistical associations, and the sixth measures how far apart two groups are. These are not six independent judges. They examine different features of the same records, so agreement among them matters primarily as confirmation that a pattern exists, not that its cause has been established.
Before proceeding, a brief guide to the language of the graphs. E denotes registered voters, C ballots cast, B valid ballots, and W votes for the selected list. The primary turnout measure is C/E, whereas list support is W/B. Of the 8,392 stations, 7,856 have at least 100 registered voters and form the primary sample for most analyses. Some methods use all 8,392; others apply additional filters. The label ‘small’ also depends on the particular classification being used.
1. Descriptive statistics: a first look that must not be the last
Descriptive statistics does what should be done before sophisticated modelling: it counts, groups and compares. Imagine compiling a table containing registered voters, ballots cast, invalid ballots and votes for each list. We can calculate proportions, but the denominator matters. A 50% share of valid votes does not imply support from half of all registered voters. When calculating a group's aggregate result, we sum the votes before calculating the percentage, so a small station does not carry the same weight as one with a thousand registered voters.
The Size classification divides the primary sample by registered-voter counts so that the Small and Large groups each represent approximately 20% of the electorate. Consequently, there are 3,677 Small stations, 3,475 Middle stations and only 704 Large stations. The alternative JHK classification uses a percentile of station counts rather than the same cumulative electorate rule; its groups are therefore different. The table shows the first classification.
Table 1. Valid-vote shares by station-size group (Size; primary sample)
| Size group | Stations | Student List (%) | Vučić list (%) |
| Small | 3,677 | 41.38 | 50.60 |
| Middle | 3,475 | 55.69 | 37.79 |
| Large | 704 | 60.84 | 32.66 |
Source: Kovačić (2026), Chapters 4 and 6 (Table 6.1). Shares are weighted by valid ballots.
At Small stations the Vučić list leads by 9.22 percentage points, whereas at Large stations the Student List leads by 28.18 points. The Middle group is not merely a transition between extremes: it contains a substantial part of the electorate, and the Student List already has a clear advantage there. The effective number of electoral options is 2.33 at Small stations and 2.09 at Large stations, suggesting somewhat greater fragmentation at smaller stations. However, it does not identify whose potential voters the smaller lists attracted, or whether those lists were formed with that intention. Descriptive analysis identifies a question to investigate rather than an answer to assume.
2. Klimek cumulative curves: where do the votes accumulate?
Imagine sorting polling stations from the lowest to the highest turnout. We then add the votes for a particular list, station by station. The horizontal axis shows the turnout threshold we have reached; the vertical axis shows the cumulative result. Dividing cumulative list votes by all valid ballots in the selected group produces a curve ending at the list's overall share. Dividing instead by all votes for the list produces a curve ending at 100%, showing how much of its total support has already been accumulated. This ordering is not chronological: we are not watching voting unfold during election day.
Why are these curves useful? A sharp rise near very high turnout would show that a considerable number of votes accumulate in that region of the distribution. Yet it would not establish ballot stuffing. There may simply be many voters or large stations at those turnout levels. It is therefore helpful to ask what proportion of each list's own votes came from stations above a particular turnout threshold.
In the primary national sample, 6.06% of all Student List votes and 6.72% of all Vučić-list votes came from stations with turnout above 80%; above 85%, the corresponding shares were 1.45% and 1.81%. The main curves largely flatten towards the upper turnout tail rather than rising dramatically. Belgrade presents an even smaller contrast: 2.46% and 2.43% of the respective lists’ votes came from stations above 80% turnout. These findings tell us where the votes are located, but they do not supply a model of how those same elections would have unfolded without irregularities.
3. Election fingerprints: a map, not a portrait of a culprit
Each polling station can be represented by a dot. Turnout lies along the horizontal axis and the selected list's share of valid votes along the vertical axis. Thousands of dots overlap, so we can colour regions containing many stations or estimate a smooth two-dimensional density (KDE). Think of this as a topographical map: a density peak is a hill in a region containing many polling stations with similar characteristics. The colours represent concentration, not suspicion.
The main peak of the national Student List fingerprint lies at approximately 72.75% turnout and 54.25% support; the Vučić-list peak lies at 72.75% turnout and 41.25% support. Why is peak turnout the same? We are examining largely the same polling stations, with the same turnout figures, but two different distributions of votes. Why need the peak share differ from the overall election result? The peak describes the most concentrated region of the station-level density, whereas the national share is calculated from summed votes, giving larger stations more weight.
When fingerprints are separated by station size, the concentration of Student List support shifts upwards from Small to Large stations; for the Vučić list, it moves in the opposite direction. This visually reinforces the table's findings, but multiple peaks or an elongated fingerprint can also arise when local communities vote differently. A fingerprint helps us ask more focused questions, not colour every unusual region as evidence of guilt.
4. Standardized contour diagrams: comparing a station with its surroundings
A Belgrade polling station and one in Toplica district may have very different vote shares without any irregularity. Instead of comparing them directly, we can calculate how far each station departs from the average and usual spread of other stations in its municipality. A standardized support value of +1 means approximately one local standard deviation above the reference mean; −1 means below it. Both turnout and support are expressed relative to a local reference, and contours connect regions of similar estimated density. Think again of a map, but one centred on local rather than national reference values.
Nationally, 7,816 of the 7,856 primary-sample stations were eligible for this standardization; 40 lacked a suitable municipal reference group. Mean standardized support for the Student List is −0.281 at Small and +0.247 at Large stations under Size classification; for the Vučić list the corresponding values are +0.268 and −0.238. The alternative JHK classification shows the same direction. Thus the contrast is not merely a product of comparing municipalities with different averages, although standardization cannot eliminate differences between rural and urban communities within the same municipality. Contours also depend on smoothing and group sizes: two Size Large stations in Toplica are insufficient for the corresponding contour pair. An unavailable plot is not evidence that a difference is absent.
5. Regression analysis: one straight line, many possible stories
Regression summarizes the relationship between two quantities with a line that best describes their average association according to the chosen criterion. In Model A, turnout C/E is on the horizontal axis and list votes per 100 registered voters (W/E expressed as a percentage) on the vertical axis. A slope of 0.685 means a ten-percentage-point turnout difference is associated with approximately 6.85 points’ difference in list votes per 100 registered voters. This compares polling stations; it is not an experiment in which we caused additional people to vote.
Table 2. Model A slopes by area (C/E)
| Area | Stations | Student List | Vučić list |
| Serbia | 7,856 | 0.685 | 0.460 |
| Belgrade | 1,266 | 0.746 | 0.205 |
| Toplica | 157 | 0.218 | 0.721 |
Source: Kovačić (2026), Table 8.1. Slopes express an association, not an estimate of manipulated votes.
The national slopes for the Student and Vučić lists are 0.685 and 0.460, but the association is much stronger for the Student List in Belgrade and for the Vučić list in Toplica. One national average can therefore conceal regional differences. Moreover, list votes form part of the total ballots, and both variables share denominator E. A positive slope is not surprising in itself and is not a count of added ballots. In additional models for the Student List, the relationship between its support and invalid-ballot counts changes when turnout and station size are included. This is a reminder that statistical associations can change when we define the comparison more carefully. Confidence intervals describe uncertainty about estimated associations under model assumptions, not proof of causation.
6. Diagnosing Small–Large differences: why do the two curves resemble each other?
If standardized contours are a map, D(p) is a ruler. For two groups of stations we identify typical positions using the medians of standardized turnout and list support, then measure the distance between these positions in two dimensions. If the turnout difference is small but the support difference is large, the ruler's length is determined primarily by support. D is always nonnegative: it tells us the size of the difference, not its direction.
The horizontal axis of Figure 1 is the percentile threshold p based on registered-voter counts, after local standardization and elliptical filtering. At p = 10%, we compare approximately the smallest ten percent of retained stations with the remaining ninety percent, not with the largest ten percent. At p = 50%, we compare two approximately equal halves; at p = 90%, the bottom ninety percent is compared with the largest ten percent. This differs from the fixed Size classification used in Method 1. The vertical axis is D(p) in standardized units, not percentages of votes. The higher the line, the further apart the two group centres are at that threshold.

Figure 1. D(p) curves, Serbia, C/E. Shared vertical scale; the two points mark p = 10%.
Read from left to right. At very low thresholds, we compare only very small stations with the others. The curves are higher and less stable there because the Small group contains few observations. As the threshold moves right, larger stations enter the lower group and the composition of the other group changes as well. Here the separation generally decreases, although not monotonically. At the 10% threshold, D is 0.818 for the Student List and 0.800 for the Vučić list; at 50%, it is approximately 0.656 and 0.588. The difference does not disappear when we change the grouping rule. Yet the height of the curve has no internationally established meaning as a boundary between ‘normal’ and ‘suspicious’ results.
Why do the curves resemble each other so closely? Consider the components of the distance at the 10% threshold.
Table 3. Why D(10) is similar: signed components (Serbia, C/E)
| List | Turnout difference | Support difference | D(10) |
| Student List | −0.081 | −0.814 | 0.818 |
| Vučić list | −0.084 | +0.796 | 0.800 |
Source: Kovačić (2026), Table 9.2. Small minus remaining stations; differences in median standardized coordinates, not percentage points.
Typical standardized turnout is slightly lower at Small stations for both lists, but the difference is small. For the Student List, standardized support is 0.814 units lower in the Small group; for the Vučić list, it is 0.796 units higher. Picture two arrows of almost equal length pointing in opposite vertical directions. The ruler measures their length, not their direction. That is why the two graphs look so similar despite opposite political directions. The lists’ vote shares are competing parts of the same total valid vote. The similarity is not two independent pieces of evidence of voter pressure; it is understandable in the presence of a common pattern. In particular, these results do not establish a combination of higher turnout and greater Vučić-list support at Small stations.
In eight exploratory within-municipality randomizations, covering thresholds of 10% and 20% and two turnout definitions, none of the 199 permutation values per combination reached the observed D. The empirical upper-tail probability is 0.005, the lower resolution limit of this procedure. This indicates a substantial contrast relative to the specific within-municipality exchangeability assumption. But that assumption is not a model of every fair election or the internationally calibrated δ(p) statistic. Villages and urban neighbourhoods are not randomly assigned to station sizes, and alternative explanations remain possible.
The same story in percentages: cumulative vote shares by size
For readers unfamiliar with standardized units, Figure 2 provides a more direct illustration. We now order stations from largest to smallest and recalculate the aggregate share of valid votes as each station is included. When approximately the largest 10% of all 8,392 stations are included, the Student List has 60.90% and the Vučić list 32.78%; including all stations gives 53.69% and 39.48%. Belgrade shows almost no net change of this kind, while Toplica shows the same direction as the national comparison. The dashed 50% line is a majority landmark, not a fraud threshold.

Figure 2. Cumulative valid-vote shares, largest to smallest stations (all 8,392). Horizontal axis expressed as percentage of station count.
The cumulative curve is not a cumulative sum of D(p): it displays a different statistic on a different sample. Successive D values are computed from overlapping groups; summing them would produce an increasing curve almost by definition, not an accumulation of independent evidence. The two illustrations are therefore complementary. One measures separation between relative local profiles; the other shows how the aggregate electoral balance changes when smaller stations are included. Neither tells us what would have happened if voters at small stations had voted like those at large stations, and neither justifies discarding their votes.
What have we learned so far?
Six procedures bring us back to the same important finding: polling-station size is associated with support for the leading lists, and geography changes the intensity and sometimes the character of those associations. This is more informative than a single striking chart, but it is not six independent confirmations of the same unlawful mechanism. Can the observed features be distinguished from those arising in ordinary, heterogeneous election data? In Part Three we turn to distributions, Monte Carlo simulations and parametric models, and explain why the alarm that did not ring matters too.
Kovačić, Z. J. (2026). Forensic analysis of the parliamentary election in Serbia, 2026. Chapters 2–14 (https://ko-fi.com/s/32015b2e23);
Election Forensics R Toolkit: https://github.com/MyStatisticalConsultant/election-forensics-r-toolkit
Director of Wellington based My Statistical Consultant Ltd company. Retired Associate Professor in Statistics.
Has a PhD in Statistics and over 45 years experience as a university professor, consultant, international researcher and government advisor.